Version history for SA21GFB01 - SA21GFB01

Version: 1.0.6

  • lastVersion: 1.0.5
  • curator: nicholas
  • timestamp: 2025-06-23 16:14:54.376337 UTC
  • changes:
    • Paleo Column metadata:
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Ce (GBRCD.SA21GFB01.Ce): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Ce (GBRCD.SA21GFB01.Ce): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • CeCe_anom (GBRCD.SA21GFB01.CeCe_anom): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Dy (GBRCD.SA21GFB01.Dy): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Dy (GBRCD.SA21GFB01.Dy): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Er (GBRCD.SA21GFB01.Er): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Er (GBRCD.SA21GFB01.Er): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Eu (GBRCD.SA21GFB01.Eu): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Eu (GBRCD.SA21GFB01.Eu): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Gd (GBRCD.SA21GFB01.Gd): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Gd (GBRCD.SA21GFB01.Gd): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Ho (GBRCD.SA21GFB01.Ho): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Ho (GBRCD.SA21GFB01.Ho): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • La (GBRCD.SA21GFB01.La): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • La (GBRCD.SA21GFB01.La): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Lu (GBRCD.SA21GFB01.Lu): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Lu (GBRCD.SA21GFB01.Lu): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Nd (GBRCD.SA21GFB01.Nd): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Nd (GBRCD.SA21GFB01.Nd): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • NdYb (GBRCD.SA21GFB01.NdYb): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Pr (GBRCD.SA21GFB01.Pr): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Pr (GBRCD.SA21GFB01.Pr): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Sm (GBRCD.SA21GFB01.Sm): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Sm (GBRCD.SA21GFB01.Sm): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • SrCa (GBRCD.SA21GFB01.SrCa): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • SrCa (GBRCD.SA21GFB01.SrCa): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Tb (GBRCD.SA21GFB01.Tb): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Tb (GBRCD.SA21GFB01.Tb): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Tm (GBRCD.SA21GFB01.Tm): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Tm (GBRCD.SA21GFB01.Tm): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Y (GBRCD.SA21GFB01.Y): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Y (GBRCD.SA21GFB01.Y): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • Yb (GBRCD.SA21GFB01.Yb): paleoData_measurementInstrument: ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’ has been replaced by ‘Thermo X Series II ICP-MS’
      • Yb (GBRCD.SA21GFB01.Yb): paleoData_notes: ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. NdYB normalised relative to Post Archean Australian Shale. REEs measured.’ has been replaced by ‘Slices were pre-treated with 10% hydrogen peroxide for 48 hr to oxidise organics and subsequently ultrasonically rinsed and oven dried. Manually collected using a drill with a 2 mm diameter bit to collect a minimum of 12 sequential samples per annual band. JCp-1 & analytical precision reported from Saha et al. (2021). See Saha et al. (2021) supplementary for all analytical precision results. Complete machine details as per Saha et al. (2021) is Thermo X-series II ICP-MS with a CETAC - 500 auto-sampler, electron spray PC3 Peltier cooled cyclonic spray chamber and SC-FAST injection loop. REEs measured.’
      • year (GBRCD.SA21GFB01.year): paleoData_isPrimary: ‘FALSE’ has been replaced by ‘TRUE’

Version: 1.0.5

  • lastVersion: 1.0.4
  • curator: nicholas
  • timestamp: 2024-04-12 15:48:55 UTC
  • changes:
    • Base metadata:
    • Publication metadata:
      • pub1_doi: ‘10.1016/j.gca.2021.02.014.’ has been replaced by ‘10.1016/j.gca.2021.02.014’
      • pub2_citation: ‘Saha, N., Webb, G.E., Zhao, J.-X., Nguyen, A.D., Lewis, S.E. & Lough, J.M. (2019), ’Coral-based high-resolution rare earth element proxy for terrestrial sediment discharge affecting coastal seawater quality, Great Barrier Reef’, Geochimica et Cosmochimica Acta, 254, 173-191, 10.1016/j.gca.2019.04.004’ has been replaced by ‘Saha, N., Webb, G.E., Zhao, J.-X., Nguyen, A.D., Lewis, S.E. & Lough, J.M. (2019), ’Coral-based high-resolution rare earth element proxy for terrestrial sediment discharge affecting coastal seawater quality, Great Barrier Reef’, Geochimica et Cosmochimica Acta, 254, 173-191, 10.1016/j.gca.2019.04.004.’
      • pub1_altDataURL: NULL has been replaced by ‘https://ars.els-cdn.com/content/image/1-s2.0-S0016703721001095-mmc1.pdf
    • Geographic metadata:
      • geo_notes: ‘3-4 m’ has been replaced by ‘3-4 m depth as per AIMS’ coral core database.’
    • Paleo Column metadata:
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_description: ‘Barium/Calcium For laser ablation datasets this is a measure of the total Ba/Ca using the count intensities of the Ba137 isotope.’ has been replaced by ‘Barium/Calcium. For laser ablation datasets this is a measure of the total Ba/Ca using the count intensities of the Ba137 isotope.’

Version: 1.0.4

  • lastVersion: 1.0.3
  • curator: nicholas
  • timestamp: 2024-04-12 15:37:22 UTC
  • notes: added isPrimary, primaryAgeColumn, and hasTimeTsid
  • changes:
    • Paleo Column metadata:
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Ce (GBRCD.SA21GFB01.Ce): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Ce (GBRCD.SA21GFB01.Ce): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • CeCe_anom (GBRCD.SA21GFB01.CeCe_anom): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • CeCe_anom (GBRCD.SA21GFB01.CeCe_anom): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Dy (GBRCD.SA21GFB01.Dy): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Dy (GBRCD.SA21GFB01.Dy): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Er (GBRCD.SA21GFB01.Er): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Er (GBRCD.SA21GFB01.Er): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Eu (GBRCD.SA21GFB01.Eu): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Eu (GBRCD.SA21GFB01.Eu): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Gd (GBRCD.SA21GFB01.Gd): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Gd (GBRCD.SA21GFB01.Gd): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Ho (GBRCD.SA21GFB01.Ho): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Ho (GBRCD.SA21GFB01.Ho): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • La (GBRCD.SA21GFB01.La): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • La (GBRCD.SA21GFB01.La): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Lu (GBRCD.SA21GFB01.Lu): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Lu (GBRCD.SA21GFB01.Lu): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Nd (GBRCD.SA21GFB01.Nd): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Nd (GBRCD.SA21GFB01.Nd): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • NdYb (GBRCD.SA21GFB01.NdYb): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • NdYb (GBRCD.SA21GFB01.NdYb): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Pr (GBRCD.SA21GFB01.Pr): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Pr (GBRCD.SA21GFB01.Pr): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Sm (GBRCD.SA21GFB01.Sm): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Sm (GBRCD.SA21GFB01.Sm): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • SrCa (GBRCD.SA21GFB01.SrCa): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • SrCa (GBRCD.SA21GFB01.SrCa): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Tb (GBRCD.SA21GFB01.Tb): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Tb (GBRCD.SA21GFB01.Tb): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Tm (GBRCD.SA21GFB01.Tm): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Tm (GBRCD.SA21GFB01.Tm): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Y (GBRCD.SA21GFB01.Y): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Y (GBRCD.SA21GFB01.Y): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • Yb (GBRCD.SA21GFB01.Yb): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • Yb (GBRCD.SA21GFB01.Yb): paleoData_primaryAgeColumn: NULL has been replaced by ‘FALSE’
      • year (GBRCD.SA21GFB01.year): paleoData_isPrimary: NULL has been replaced by ‘FALSE’
      • year (GBRCD.SA21GFB01.year): paleoData_primaryAgeColumn: NULL has been replaced by ‘TRUE’

Version: 1.0.3

  • lastVersion: 1.0.2
  • curator: nicholas
  • timestamp: 2024-03-22 22:54:18 UTC
  • changes:
    • Publication metadata:
    • Paleo Column metadata:
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_description: ‘Barium/Calcium. Assumed to be Ba137/Ca.’ has been replaced by ‘Barium/Calcium For laser ablation datasets this is a measure of the total Ba/Ca using the count intensities of the Ba137 isotope.’
      • CeCe_anom (GBRCD.SA21GFB01.CeCe_anom): paleoData_description: ‘Cerium anomaly calculated as per Lawrence et al. 2006’ has been replaced by ‘Cerium anomaly calculated as per Lawrence et al. (2006).’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_description: ‘Yttrium/Holmium as mass ratio’ has been replaced by ‘Yttrium/Holmium as mass ratio.’

Version: 1.0.2

  • lastVersion: 1.0.1
  • curator: nicholas
  • timestamp: 2024-03-09 00:06:32 UTC
  • changes:
    • Paleo Column metadata:
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_uncertaintyAnalytical: NULL has been replaced by ‘0.8’
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_uncertaintyAnalyticalUnits: NULL has been replaced by ‘%’
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • BaCa (GBRCD.SA21GFB01.BaCa): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Ce (GBRCD.SA21GFB01.Ce): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Ce (GBRCD.SA21GFB01.Ce): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Dy (GBRCD.SA21GFB01.Dy): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Dy (GBRCD.SA21GFB01.Dy): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Er (GBRCD.SA21GFB01.Er): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Er (GBRCD.SA21GFB01.Er): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Eu (GBRCD.SA21GFB01.Eu): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Eu (GBRCD.SA21GFB01.Eu): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Gd (GBRCD.SA21GFB01.Gd): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Gd (GBRCD.SA21GFB01.Gd): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Ho (GBRCD.SA21GFB01.Ho): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Ho (GBRCD.SA21GFB01.Ho): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • La (GBRCD.SA21GFB01.La): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • La (GBRCD.SA21GFB01.La): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Lu (GBRCD.SA21GFB01.Lu): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Lu (GBRCD.SA21GFB01.Lu): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_uncertaintyAnalytical: NULL has been replaced by ‘4.5’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_uncertaintyAnalyticalUnits: NULL has been replaced by ‘%’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • MnCa (GBRCD.SA21GFB01.MnCa): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Nd (GBRCD.SA21GFB01.Nd): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Nd (GBRCD.SA21GFB01.Nd): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • NdYb (GBRCD.SA21GFB01.NdYb): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • NdYb (GBRCD.SA21GFB01.NdYb): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Pr (GBRCD.SA21GFB01.Pr): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Pr (GBRCD.SA21GFB01.Pr): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_uncertaintyAnalytical: NULL has been replaced by ‘4.5’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_uncertaintyAnalyticalUnits: NULL has been replaced by ‘%’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Sm (GBRCD.SA21GFB01.Sm): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Sm (GBRCD.SA21GFB01.Sm): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • SrCa (GBRCD.SA21GFB01.SrCa): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • SrCa (GBRCD.SA21GFB01.SrCa): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Tb (GBRCD.SA21GFB01.Tb): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Tb (GBRCD.SA21GFB01.Tb): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Tm (GBRCD.SA21GFB01.Tm): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Tm (GBRCD.SA21GFB01.Tm): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Y (GBRCD.SA21GFB01.Y): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Y (GBRCD.SA21GFB01.Y): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_uncertaintyAnalytical: NULL has been replaced by ‘1.4’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_uncertaintyAnalyticalUnits: NULL has been replaced by ‘%’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • YCa (GBRCD.SA21GFB01.YCa): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • YHo (GBRCD.SA21GFB01.YHo): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’
      • Yb (GBRCD.SA21GFB01.Yb): paleoData_measurementInstrument: NULL has been replaced by ‘Thermo X Series II Inductively Coupled Plasma-Mass Spectrometer’
      • Yb (GBRCD.SA21GFB01.Yb): paleoData_measurementMethod: NULL has been replaced by ‘ICP-MS’

Version: 1.0.1

  • lastVersion: 1.0.0
  • curator: nicholas
  • timestamp: 2024-02-16 22:34:13 UTC
  • changes:
    • Paleo Interpretation metadata:
      • BaCa (GBRCD.SA21GFB01.BaCa): interpretation1_scope: NULL has been replaced by ‘climate’
      • Ce (GBRCD.SA21GFB01.Ce): interpretation1_scope: NULL has been replaced by ‘climate’
      • CeCe_anom (GBRCD.SA21GFB01.CeCe_anom): interpretation1_scope: NULL has been replaced by ‘climate’
      • Dy (GBRCD.SA21GFB01.Dy): interpretation1_scope: NULL has been replaced by ‘climate’
      • Er (GBRCD.SA21GFB01.Er): interpretation1_scope: NULL has been replaced by ‘climate’
      • Eu (GBRCD.SA21GFB01.Eu): interpretation1_scope: NULL has been replaced by ‘climate’
      • Gd (GBRCD.SA21GFB01.Gd): interpretation1_scope: NULL has been replaced by ‘climate’
      • Ho (GBRCD.SA21GFB01.Ho): interpretation1_scope: NULL has been replaced by ‘climate’
      • La (GBRCD.SA21GFB01.La): interpretation1_scope: NULL has been replaced by ‘climate’
      • Lu (GBRCD.SA21GFB01.Lu): interpretation1_scope: NULL has been replaced by ‘climate’
      • MnCa (GBRCD.SA21GFB01.MnCa): interpretation1_scope: NULL has been replaced by ‘climate’
      • Nd (GBRCD.SA21GFB01.Nd): interpretation1_scope: NULL has been replaced by ‘climate’
      • NdYb (GBRCD.SA21GFB01.NdYb): interpretation1_scope: NULL has been replaced by ‘climate’
      • Pr (GBRCD.SA21GFB01.Pr): interpretation1_scope: NULL has been replaced by ‘climate’
      • REEsCa (GBRCD.SA21GFB01.REEsCa): interpretation1_scope: NULL has been replaced by ‘climate’
      • Sm (GBRCD.SA21GFB01.Sm): interpretation1_scope: NULL has been replaced by ‘climate’
      • SrCa (GBRCD.SA21GFB01.SrCa): interpretation1_scope: NULL has been replaced by ‘climate’
      • Tb (GBRCD.SA21GFB01.Tb): interpretation1_scope: NULL has been replaced by ‘climate’
      • Tm (GBRCD.SA21GFB01.Tm): interpretation1_scope: NULL has been replaced by ‘climate’
      • Y (GBRCD.SA21GFB01.Y): interpretation1_scope: NULL has been replaced by ‘climate’
      • YCa (GBRCD.SA21GFB01.YCa): interpretation1_scope: NULL has been replaced by ‘climate’
      • YHo (GBRCD.SA21GFB01.YHo): interpretation1_scope: NULL has been replaced by ‘climate’
      • Yb (GBRCD.SA21GFB01.Yb): interpretation1_scope: NULL has been replaced by ‘climate’

Version: 1.0.0

  • curator: arzey
  • timestamp: 2024-02-09 04:32:39.920523 UTC
  • notes: Starting the changelog